⚡ OffGrid Sizer

Home › Generators & home backup

Generator fuel & runtime calculator

Estimate how long a generator runs on a tank, how much gasoline or propane a multi-day outage takes and what it costs, from your generator's fuel-use spec.

Results

Runtime per tank10 hours
Fuel needed for the outage14.4 gal
Fuel cost for the outage$50.4
Tank fills needed4 fills
Fuel per day4.8 gal/day
  • Store fuel only in approved containers, with stabilizer added for gasoline older than a month. Check local limits on how much you can store at home.
  • Never run a generator indoors, in a garage or near windows. Carbon monoxide kills. Place it at least 20 ft from the house with the exhaust pointing away.

About this calculator

Fuel is what a generator plan usually runs short on. Stations lose power in widespread outages too, and gasoline goes stale in storage. Knowing how many gallons a three-day outage takes tells you how much to keep on hand and whether a dual-fuel or propane setup makes more sense.

Manufacturers publish fuel use as a runtime table, for example "8 hours at 50% load on a full tank". Enter that rate, how long outages last where you live and how many hours a day you'll run the generator. You get runtime per tank, total fuel and cost.

How to use it

  1. Find fuel use in the manual or spec sheet at a load close to yours. Divide tank gallons by rated hours to get gal/h.
  2. Enter your tank size and local fuel price.
  3. Enter the outage length you're planning for and the hours you'll run per day.
  4. Plan to store the 'fuel needed' figure, with stabilizer, rotated every few months.

The formula

Runtime per tank = tank gallons ÷ gallons per hour.

Fuel needed = days × hours per day × gallons per hour.

Fuel use isn't proportional to load. A generator at 25% load typically burns roughly half of what it burns at full load, so always use the rate from the manual at a load close to yours.

Worked example (default values)

Inputs

Fuel tank size4 gal
Fuel use at your typical load0.4 gal/h
Fuel price3.5 $/gal
Outage length3 days
Hours run per day12 h/day

Results

Runtime per tank10 hours
Fuel needed for the outage14.4 gal
Fuel cost for the outage$50.4
Tank fills needed4 fills
Fuel per day4.8 gal/day

Tips and common mistakes

Propane stores indefinitely, but most dual-fuel generators lose about 10% of their rated output on it and burn it faster by volume. A 20 lb tank holds about 4.7 gallons. Convert your manual's propane runtime table the same way.

Run in cycles. A fridge stays cold for hours with the door closed. Running 2 hours on and 2 off halves fuel use with little food risk. Check food safety guidance for your situation.

Frequently asked questions

How long does a generator run on 5 gallons?

Most 5,000-7,500 W portable generators burn about 0.4-0.8 gal/h at moderate load, so about 6-12 hours. Small 2,000 W inverter generators can run 8-10 hours on about 1 gallon at 25% load.

How much gas do I need for a 3-day outage?

Running 12 hours a day at 0.5 gal/h is 18 gallons. Cycling the generator can cut that to 8-12 gallons.

Does a bigger generator use more fuel?

At the same load, usually yes, because its engine is larger and less efficient at light loads. Oversizing costs fuel.

Related calculators

Estimates for planning only, based on the assumptions shown. Real-world performance varies with equipment, temperature and installation. Updated October 19, 2026. See our methodology.